Slot: measurements
The measurements a diagnostic test consists of, each bound to LOINC. The diagnosis_term says what kind of procedure the test is (an NCIT clinical intervention: enzyme assay, molecular genetic testing); measurements say which observables it reads: hexosaminidase A activity in leukocytes, a CFTR sequencing panel, the PHQ-9 total score. The same action/thing split as treatment_term and therapeutic_agent.
URI: dismech:slot/measurements
Alias: measurements
Applicable Classes
Properties
Type and Range
Cardinality and Requirements
| Property |
Value |
| Multivalued |
Yes |
- One entry per distinct measurement. A two-analyte test is two entries.
- Bind the LOINC Part or the panel / total-score code for the measurement's identity, not a method- or specimen-specific code; LOINC has dozens of codes for one assay, and binding method codes here puts the same test on different codes in different entries. Method codes belong in a definitions[] phenotype algorithm.
- preferred_term is the curator's name for the measurement in this disease ("sweat chloride"); term.label is the Long Common Name.
- Decision thresholds the disease owns (a diagnostic cut-off, a severity grading) go in the sibling reference_ranges, keyed on the same LOINC code via loinc_term.
Schema Source
- from schema: https://w3id.org/monarch-initiative/dismech
Mappings
| Mapping Type |
Mapped Value |
| self |
dismech:measurements |
| native |
dismech:measurements |
LinkML Source
name: measurements
description: 'The measurements a diagnostic test consists of, each bound to LOINC.
The diagnosis_term says what kind of procedure the test is (an NCIT clinical intervention:
enzyme assay, molecular genetic testing); measurements say which observables it
reads: hexosaminidase A activity in leukocytes, a CFTR sequencing panel, the PHQ-9
total score. The same action/thing split as treatment_term and therapeutic_agent.'
comments:
- One entry per distinct measurement. A two-analyte test is two entries.
- Bind the LOINC Part or the panel / total-score code for the measurement's identity,
not a method- or specimen-specific code; LOINC has dozens of codes for one assay,
and binding method codes here puts the same test on different codes in different
entries. Method codes belong in a definitions[] phenotype algorithm.
- preferred_term is the curator's name for the measurement in this disease ("sweat
chloride"); term.label is the Long Common Name.
- Decision thresholds the disease owns (a diagnostic cut-off, a severity grading)
go in the sibling reference_ranges, keyed on the same LOINC code via loinc_term.
from_schema: https://w3id.org/monarch-initiative/dismech
rank: 1000
alias: measurements
domain_of:
- Diagnosis
range: MeasurementDescriptor
multivalued: true
inlined: true
inlined_as_list: true